KNOX ASW10K-LT-G2 (10 KW)


Categories: KNOX INVERTERSON GRID INVERTERS

Technical Data SheetASW 8K-LT-G2ASW 10K-LT-G2ASW 12K-LT-G2
AC connectionplug- in connectorplug- in connectorplug- in connector
AC Grid frequency16.8 A16 A19.1 A
AC nominal voltage220 V/ 380 V -230 V / 400 V -240 V/ 425 V220 V/ 380 V -230 V / 400 V -240 V/ 425 V220 V/ 380 V -230 V / 400 V -240 V/ 425 V
AC voltage range160 V TO 300 V160 V TO 300 V160 V TO 300 V
Adjustable Displacement0.8 overexcited to 0.8 underexcited0.8 overexcited to 0.8 underexcited0.8 overexcited to 0.8 underexcited
ALL-pole- sensitive residual- current monitoring unit17. 3 KG17. 3 KG17. 3 KG
Certificate ad approvals ( more available on request)CE,EN 50549, 1EC 62109, IEC 62116, IEC 61727, IEC 616 83, IEC 60068, 1EC 60068,IEC 6100,AS/NZS4777,C10/C11CE,EN 50549, 1EC 62109, IEC 62116, IEC 61727, IEC 616 83, IEC 60068, 1EC 60068,IEC 6100,AS/NZS4777,C10/C11CE,EN 50549, 1EC 62109, IEC 62116, IEC 61727, IEC 616 83, IEC 60068, 1EC 60068,IEC 6100,AS/NZS4777,C10/C11
Climatic category ( according to IEC 60721- 3-44K4H4K4H4K4H
Communication interfacewi-Fi/ Rs485wi-Fi/ Rs485wi-Fi/ Rs485
Cooling ConceptActive coolingActive coolingActive cooling
CS reverse polarity protection/ AC Short circuit current capability.
DC connectionPhoenix contactPhoenix contactPhoenix contact
Degree of protection ( according to IEC 60529IP65IP65IP65
Dimension ( w/h/ d)
Efficiency and Protection
Features
feed-in phase333
General Data
Ground fault monitoring
grid monitoring
Harmonic Distortion (THD) at rated out put<3%<3%<3%
Initial Feed- in voltage150 V150 V150 V
Input DC
LED indicator ( status/ Fault/ Communication
Main Input voltage125 V125 V125 V
Max apparent AC Power8000VA10000 V A12000 V A
Max efficiency / European efficiency98.6 % / 98.2 %98.6 % / 98.2 %98.6 % / 98.2 %
Max in put voltage1100 v1100 v1100 v
Max operating altitude3000 M3000 M3000 M
Max Operating input current26 A /13 A26 A /13 A40 A / 40 A
Max Output Current0.8 overexcited to 0.8 underexcited0.8 overexcited to 0.8 underexcited0.8 overexcited to 0.8 underexcited
Max permissible valuable for relative Humidity ( non- condensing)100%100%100%
Max PV array Power12000 WP STC15000 WP STC18000 WP STC
Max short circuit current40 A / 20 A40 A / 20 A2/A:2; B:1
Number of independent MPP inputs/ String per MPP input2/A:1; B:12/A:1; B:1
Operating temperature range-25 C -+60 C-25 C -+60 C-25 C -+60 C
OUTPUT AC
Power factor at rated active power111
Protection class( according ti IEC 62109-1)/ overvoltage category( according to IEC 62109-1)I/AC: III; DC: III/AC: III; DC: III/AC: III; DC: II
Rated grid frequency / rated grid voltage50 HZ/ 230 V
Rated active power8000 W10000 W12000 W
Self Consumption (at night)<1W<1W<1W
TopologyTransformerlessTransformerlessTransformerless
Weight17.3 KG17.3 KG17.3 KG